Please use this identifier to cite or link to this item: https://hdl.handle.net/1/3217
Title: Temporal Trends in VA-ECMO and Concurrent Mechanical Circulatory Support for Cardiogenic Shock
Authors: Said, Christian ;Sundermeyer, Jonas;Hernandez-Montfort, Jaime;Li, Song;Kataria, Rachna;Zweck, Elric;Faugno, Anthony;Sinha, Shashank S;Abraham, Jacob;Kanwar, Manreet K;Garan, Arthur Reshad;Ton, Van-Khue;Mahr, Claudius;Sangal, Paavni;Natov, Peter;Imran Aslam, M;Jain, Pankaj;Hayward, Christopher;Burkhoff, Daniel;Lorusso, Roberto;Kapur, Navin K
Affliation: Central Coast Local Health District
Gosford Hospital
Issue Date: 11-Sep-2026
Source: Online ahead of print
Journal title: The Journal of Heart and Lung Transplantation
Department: Cardiology
Abstract: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is often combined with other temporary mechanical circulatory support (tMCS) in cardiogenic shock, yet combination-specific outcomes remain poorly defined. We compared temporal trends, mortality, complications, and device sequencing across VA-ECMO strategies. VA-ECMO patients in the Cardiogenic Shock Working Group registry were analyzed. Patients were grouped as VA-ECMO alone or by first overlapping device: Impella CP, Impella 5.5, or intra-aortic balloon pump (IABP). The primary outcome was in-hospital mortality. Multivariable logistic regression assessed associations with mortality. Of 11,386 cardiogenic shock patients, 1,502 (13.2%) received VA-ECMO, of whom 759 (50.5%) had concurrent tMCS [321 (21.4%) Impella CP, 208 (13.8%) Impella 5.5, and 230 (15.3%) IABP]. Concurrent Impella 5.5 was associated with lower mortality compared to VA-ECMO alone (aOR 0.62, 95% CI 0.45-0.86; P=0.004); no significant difference was observed for Impella CP or IABP. Overall mortality was 48.4%, higher with acute myocardial infarction (AMI) than heart failure shock (58.7% vs 40.9%; P<0.001). Across registry versions (2021-2025), isolated VA-ECMO use remained stable over time (45.0% to 48.9%; P for trend = 0.950), microaxial flow pump use increased (32.2% to 40.2%; P = 0.005), and IABP use declined (22.8% to 10.9%; P < 0.001). Anoxic brain injury was most strongly associated with mortality (aOR 10.51, 95% CI 6.26-17.64; P<0.001). More than half of VA-ECMO patients received a concurrent device, with increasing microaxial flow pump and declining IABP use. Complications and mortality differed across strategies and shock etiologies.
URI: https://hdl.handle.net/1/3217
DOI: 10.1016/j.healun.2026.09.003
Pubmed: https://pubmed.ncbi.nlm.nih.gov/42727718
Publicaton type: Journal Article
Keywords: Cardiology
Hear Disease
Appears in Collections:Cardiology

Show full item record

Page view(s)

58
checked on Oct 8, 2026

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.