Title: | Foreign body in the middle ear, a hearing aid complication | Authors: | Shashinder, Singh ;Tang, I.P.;Velayutham, P.;Rahmat, O.;Loganathan, A. | Issue Date: | Aug-2008 | Source: | Volume 63, Issue 3, pp. 267 - 268 | Journal title: | The Medical Journal of Malaysia | Department: | General Surgery | Abstract: | A 12-year-old boy with moderate to severe bilateral mixed hearing loss was planned for hearing aid placement. During the process of making ear mould impression, the impression material accidentally entered the right middle ear. Removal of the ear mould impression was possible permeatally under general anaesthesia. | URI: | https://elibrary.cclhd.health.nsw.gov.au/cclhdjspui/handle/1/1933 | Pubmed: | https://pubmed.ncbi.nlm.nih.gov/19248709/ | ISSN: | 0300-5283 | Publicaton type: | Journal Article | Keywords: | Surgery Child |